Powder-free latex surgical glove
loading

Innovation designed for controlled grip


Applications

Orthopaedic surgery

Trauma surgery

Cardiothoracic surgery

Features and Benefits

Best-in-class grip for precise instrument handling

  • Precision grip
  • Controlled manipulation of instruments
  • Sure handling in all conditions
Ensuring these essentials is what Ansell Gammex® PF HyGrip™ is all about. Whether worn during conventional procedures or used for orthopaedic applications utilising special instruments that require excellent grip, the glove’s micro-roughened surface prevents instruments from getting slippery even when exposed to fatty tissue or synovial fluids. The result is a controlled grip for higher precision and increased safety.

Low allergenicity

Users of Ansell Gammex® PF HyGrip™ benefit from reduced risk of latex sensitisation. This is ensured through leaching processes and post-production washing cycles, such as Ansell’s Protein and Endogenous Allergen Reduction Leaching (P.E.A.R.L) technology. HPLC and Modified Lowry methods are used to measure protein content. The risk for Type IV allergy is reduced because Ansell’s unique accelerator is completely consumed during the manufacturing process.

Positive customer feedback

Early testing conducted with customers indicated that almost 2/3 of orthopaedic surgeons gave Gammex® PF HyGrip™ a score of 'GOOD TO EXCELLENT'. All users felt the product provided a significantly improved grip.

Safety

Safety is assured through quality controls before, during and after final packaging, guaranteeing a low risk of pinholes and high barrier protection.
  • Quality control is assured, based on AQL inspection procedures (water leak tested): conformity to European norm EN 455-1: inspection level I AQL 1.5, manufacturing final release: inspection level I AQL 1.0, in process control before packaging: inspection level II AQL 0.65
  • Resistant to alcohol-based hand disinfectants: the inner coating maintains its integrity – even during long procedures.
  • Strong resistance to viral penetration is verified by extensive bacteriophage test results (see the Ansell AVPP brochure).
  • Greater patient protection, based on close monitoring of pyrogen and endotoxin levels (biocompatibility test as per ISO 10993).
  • Low particle levels result from limited residual production-based powder (releasing agent).
  • Easy shelf identification, plus links to manufacturing data supported by lot numbers.

Comfort and sensitivity

Ansell provides users with the comfort and dexterity the Gammex® range is known for. Gammex® PF HyGrip™ offers the same welcome ergonomic features, including a specially designed surface for safe and secure instrument handling without compromising good sensitivity. Thinner latex at the palm and fingers, compared to other surgical gloves, also enhances sensitivity. Gammex® PF HyGrip™ minimises hand fatigue, thanks to the use of special formers during the manufacturing process. Its unique design includes a straight cuff that relieves pressure on the forearm while operating. Moreover, the adhesive band at the top of the cuff maintains good contact with the surgical gown preventing the glove from rolling down.

Excellent for double gloving

Gammex® PF HyGrip™ is designed to be used as the top glove in double-gloving solutions when additional safety is required during high-risk procedures. The inner coating makes double gloving easy. Gammex® PF HyGrip™ combined with the Ansell Gammex® PF Underglove provides superior grip control for the wearer and excellent safety for both patient and surgeon.

Easily donned

Donning is made easy even with damp hands, thanks to the glove’s water-based synthetic (polyurethane) inner-coating. A combination of hydrophilic and hydrophobic components is integrated within the inner coating. Upon contact with wet hands, the hydrophilic components release a lubricant that improves ease of donning. The result: much easier intra-operative changes.

Double gloving for optimal protection

Combined with frequent glove changes, double gloving (wearing two pairs of gloves) is probably one of the most effective methods to reduce exposure to blood-borne pathogens, as it reduces by a factor of 10 the number of potential exposures.(1)
In a 1992 study(2) it was reported that surgeons who only single gloved had a 51% hand contamination rate versus a 7% contamination rate for surgeons who double gloved.
For more information consult the Ansell white paper: 'The value of double gloving within the operating environment'.
(1) Preventing disease in the operating room. Panel discussion. American College of Surgeons Spring Meeting. April 29, 1998.
(2) Quebbeman EJ, Telford GL, et. al. Double gloving. Protecting surgeons from blood contamination in the operating room. Arch Surg. 1992;127(2):213-216.

Packaging

40 pairs per box, 6 boxes per carton.

Specifications

Gammex® PF HyGrip™

CodeSize
3531615.5
3531626.0
3531636.5
3531647.0
3531657.5
3531668.0
3531678.5
3531689.0