Powder-free neoprene surgical glove
loading

Next generation glove solutions for allergy prevention


Features and Benefits

For all healthcare workers in a sterile environment who are sensitive to Type I and/or Type IV allergies.

Today, healthcare professionals are highly conscious of the allergic risks linked to natural or synthetic rubber latex gloves, among them Type IV allergies. Clinical evidence shows they represent up to 28% of glove-related allergic reactions, with up to 90% of these Type IV allergies due to vulcanisation accelerators*.
Vulcanisation accelerators are traditionally used to accelerate the linkage of rubber molecules in natural or synthetic rubber. Although many gloves on the market aim at minimising residual accelerators, it is impossible to define an acceptable level for these components because all allergic reactions are based on individual sensitivity.
In addition to being free of latex proteins (preventing Type I allergies), Gammex® PF DermaPrene® is accelerator-free.
*Source: Dr A Heese, University of Erlangen, 1989-1992.

Ideal for allergy prevention

Gammex® PF DermaPrene® offers a massive reduction in potential skin reactions and allergies.
  • It minimises the risk of Type IV allergies because it is free of accelerators.
  • It prevents Type I allergies because it is free of latex proteins.
  • It limits the risk of dermatitis for the wearer because it is powder-free.
  • It limits granuloma or adhesion risks for the patient because it is powder-free.

Latex-like comfort and ease-of-use

Gammex® PF DermaPrene® is constructed from a unique blend of neoprenes to provide outstanding flexibility and stretch levels in use.
Fabricated using a special former, the glove has a curved fit and a greater width across the hand. This reduces pressure on overworked areas such as the thumb ball and palm, confirmed through tests covering 10 key pressure points. The result is much higher comfort for the wearer, especially valuable during lengthy operative procedures.
An extra-length cuff with an adhesive band provides improved grip on the sleeve and prevents roll-down for a secure fit. Moreover, the film thickness is carefully controlled to ensure optimum sensitivity.

Easy donning, even with damp hands

A water-based (polyurethane) synthetic inner coating ensures easy donning on either dry or damp hands thanks to the use of hydrophobic and hydrophilic components. Hydrophobic components reduce friction and blocking. Hydrophilic components release a lubricant when in contact with wet hands, thereby improving donning and making intra-operative changes easier. This inner coating also facilitates easy double-gloving when additional safety is required.

Excellent handling and grip

The Gammex® PF DermaPrene® glove provides an excellent grip on instruments in both wet and dry conditions. This is achieved through a unique external surface treatment applied during manufacture. The grip values are continuously verified and monitored by friction testing online and during post-processing.

Unparalleled safety

As the leader in synthetic surgical gloves across Europe, Gammex® PF DermaPrene® has built a proven reputation as a reliable protective barrier. Safety is assured through quality controls before, during and after final packaging, guaranteeing a low risk of pinholes and high barrier protection.
  • Quality control is assured, based on AQL inspection procedures (water leak tested): conformity to European norm EN 455-1: inspection level I AQL 1.5, manufacturing final release: inspection level I AQL 1.0, in process control before packaging: inspection level II AQL 0.65.
  • Greater resistance to tear and puncture than most latex and other synthetic gloves.
  • Excellent fat resistance, for a longlasting glove in all kinds of surgery.
  • High resistance to alcohol and a broad range of chemical products.
  • Strong resistance to viral penetration is verified by extensive bacteriophage test results (see the Ansell AVPP brochure).
  • Greater patient protection, based on close monitoring of pyrogen and endotoxin levels (biocompatibility test as per ISO 10993).
  • Low particle levels result from limited residual production-based powder (releasing agent).
  • Easy shelf identification, plus links to manufacturing data supported by lot numbers.

Allergy risk assessment for different non-latex materials

Glove Type/MaterialContains latex proteinsContains vulcanisation acceleratorsRecommended for Type I allergiesRecommended for Type IV allergies
Gammex® PF DermaPrene® (1)NoNoYesYes
Polychloroprene (2)NoYesYesNo
PolyisopreneNoYesYesNo
CopolymerNoNoYesYes
(1) Gammex® PF DermaPrene® is based on a unique polychloroprene formulation which does not contain any chemical accelerators, is easier to don and offers better resistance to bone cement than copolymer gloves.

(2) Commercially available gloves based on polychloroprene that contain chemical accelerators.

Packaging

25 pairs per box, 4 boxes per carton.

Specifications

Gammex® PF DermaPrene®

CodeSize
3532015.5
3532026.0
3532036.5
3532047.0
3532057.5
3532068.0
3532078.5
3532089.0